Bu sayfayı referans olarak kabul etmeden önce SPBM ile alakalı yazdığım yazımı tekrar okumanızı öneririm. Sayfaya buradan ulaşabilirsiniz.
- Stretched Cluster – In Site RAID1
- Veri, her iki site’a da yazılır, ve site içinde ayrıca RAID1 yapılır, (min. 3’er sunucu)
- Storage Type -> VSAN
- Primary level of failures to tolerate -> 1
- Secondary level of failures to tolerate -> 1
- Failure tolerance method -> RAID-1 (Mirroring – Performance)
- Stretched Cluster – In Site RAID5
- Veri, her iki site’a da yazılır, ve site içinde ayrıca RAID5 yapılır, (min. 4’er sunucu)
- Storage Type -> VSAN
- Primary level of failures to tolerate -> 1
- Secondary level of failures to tolerate -> 1
- Failure tolerance method -> RAID-5/6 (Erasure Coding) – Capacity
- Stretched Cluster – In Site RAID6
- Veri, her iki site’a da yazılır, ve site içinde ayrıca RAID6 yapılır, (min. 6’şar sunucu)
- Storage Type -> VSAN
- Primary level of failures to tolerate -> 1
- Secondary level of failures to tolerate -> 2
- Failure tolerance method -> RAID-5/6 (Erasure Coding) – Capacity
- Data Locality Preferred – RAID1
- Veri, Preferred site üzerinde ve RAID1 olarak tutulur, diğer site’da veri tutulmaz.
- Storage Type -> VSAN
- Primary level of failures to tolerate -> 0
- Secondary level of failures to tolerate -> 1
- Data Locality -> Preferred Fault Domain (Stretched)
- Failure tolerance method -> RAID-1 (Mirroring – Performance)
- Data Locality Preferred – RAID5
- Veri, Preferred site üzerinde ve RAID5 olarak tutulur, diğer site’da veri tutulmaz.
- Storage Type -> VSAN
- Primary level of failures to tolerate -> 0
- Secondary level of failures to tolerate -> 1
- Data Locality -> Preferred Fault Domain (Stretched)
- Failure tolerance method -> RAID-5/6 (Erasure Coding) – Capacity
- Data Locality Preferred – RAID6
- Veri, Preferred site üzerinde ve RAID6 olarak tutulur, diğer site’da veri tutulmaz.
- Storage Type -> VSAN
- Primary level of failures to tolerate -> 0
- Secondary level of failures to tolerate -> 2
- Data Locality -> Preferred Fault Domain (Stretched)
- Failure tolerance method -> RAID-5/6 (Erasure Coding) – Capacity
- Data Locality Secondary – RAID1
- Veri, Secondary site üzerinde ve RAID1 olarak tutulur, diğer site’da veri tutulmaz.
- Storage Type -> VSAN
- Primary level of failures to tolerate -> 0
- Secondary level of failures to tolerate -> 1
- Data Locality -> Secondary Fault Domain
- Failure tolerance method -> RAID-1 (Mirroring – Performance)
- Data Locality Secondary – RAID5
- Veri, Secondary site üzerinde ve RAID5 olarak tutulur, diğer site’da veri tutulmaz.
- Storage Type -> VSAN
- Primary level of failures to tolerate -> 0
- Secondary level of failures to tolerate -> 1
- Data Locality -> Secondary Fault Domain
- Failure tolerance method -> RAID-5/6 (Erasure Coding) – Capacity
- Data Locality Secondary – RAID6
- Veri, Secondary site üzerinde ve RAID6 olarak tutulur, diğer site’da veri tutulmaz.
- Storage Type -> VSAN
- Primary level of failures to tolerate -> 0
- Secondary level of failures to tolerate -> 2
- Data Locality -> Secondary Fault Domain
- Failure tolerance method -> RAID-5/6 (Erasure Coding) – Capacity
Yorum yapılmamış
You can leave the first : )