{"id":655,"date":"2019-04-01T13:06:58","date_gmt":"2019-04-01T10:06:58","guid":{"rendered":"https:\/\/blog.arcak.net\/?p=653"},"modified":"2019-04-01T16:39:43","modified_gmt":"2019-04-01T13:39:43","slug":"dell-emc-vxrail-installation","status":"publish","type":"post","link":"https:\/\/blog.arcak.net\/index.php\/2019\/04\/01\/dell-emc-vxrail-installation\/","title":{"rendered":"Dell EMC VxRail Installation"},"content":{"rendered":"<p>In This article, I will talk about prerequisites, installation and basic issues for<strong> VxRail installation<\/strong>.<\/p>\n<p>When I created the this document, the <strong>VxRail <\/strong>version was<strong> 4.5.300<\/strong>. Therefore, it may differ with the current version.<strong> (Adding new nodes, ESRS installation, etc.)<\/strong><\/p>\n<p><span style=\"font-size: 18pt;\"><strong>Requirements (General)<\/strong><\/span><\/p>\n<table style=\"border-style: none; width: 872px; height: 408px;\" border=\"1\" width=\"880\">\n<tbody>\n<tr style=\"height: 24px;\">\n<td style=\"width: 79px; height: 24px;\"><b>Step<\/b><\/td>\n<td style=\"width: 779px; height: 24px;\"><b>Definition<\/b><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 79px; height: 24px;\"><strong>1<\/strong><\/td>\n<td style=\"width: 779px; height: 24px;\">Complete physical installations of Servers and Switches.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 79px; height: 24px;\"><strong>2<\/strong><\/td>\n<td style=\"width: 779px; height: 24px;\">Do the IDRAC and Switch BMC wiring.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 79px; height: 24px;\"><strong>4<\/strong><\/td>\n<td style=\"width: 779px; height: 24px;\">One cable from server to Tor Switch A, the second cable is to Tor Switch B.<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 79px; height: 48px;\"><strong>5<\/strong><\/td>\n<td style=\"width: 779px; height: 48px;\">Connect Tor Switches in the customer network and configure them as a stack, making sure there are no LACP on it.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 79px; height: 24px;\"><strong>3<\/strong><\/td>\n<td style=\"width: 779px; height: 24px;\">Create the corresponding VLANS on Top-Of-Rack (Tor) Switches to be used for the VxRail.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 79px; height: 24px;\"><strong>6<\/strong><\/td>\n<td style=\"width: 779px; height: 24px;\">Enable IPv4 and IPv6 multicast for the Management VLAN and IPv4 multicast for the vSAN VLAN.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 79px; height: 24px;\"><strong>6<\/strong><\/td>\n<td style=\"width: 779px; height: 24px;\">Create forward and reverse DNS records for ESXi, VCenter, and Log Insight and make sure they are resolved.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 79px; height: 24px;\"><strong>7<\/strong><\/td>\n<td style=\"width: 779px; height: 24px;\">Make sure the Customer network is accessible. <strong>(AD, DNS, Proxy, etc.)<\/strong><\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 79px; height: 48px;\"><strong>8<\/strong><\/td>\n<td style=\"width: 779px; height: 48px;\">Ensure that the ESXi servers and the NTP server show the same time, if necessary, fix the time via the IDRAC and ESXi host.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 79px; height: 24px;\"><strong>10<\/strong><\/td>\n<td style=\"width: 779px; height: 24px;\">Tagged or Untagged traffic from Tor Switch ports connected to Vxrail are allowed, decide by structure.<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 79px; height: 48px;\"><strong>11<\/strong><\/td>\n<td style=\"width: 779px; height: 48px;\">Allow all traffic to pass through ports used in connection between all switches, including IPv4 and IPv6 multicast if Multiple switches are in use.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 79px; height: 24px;\"><strong>Optional<\/strong><\/td>\n<td style=\"width: 779px; height: 24px;\">Check that the EMC support account is correct.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 79px; height: 24px;\"><strong>Optional<\/strong><\/td>\n<td style=\"width: 779px; height: 24px;\">Make sure that the Switches connected to the BMC and the IDRAC support 100Mbps.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><!--more--><\/p>\n<p><span style=\"font-size: 18pt;\"><strong>Requirements (Network)<\/strong><\/span><\/p>\n<table style=\"height: 972px; width: 750px;\" border=\"1\" width=\"838\">\n<tbody>\n<tr>\n<td style=\"width: 79px; text-align: center;\"><b>Vlan<\/b><\/td>\n<td style=\"width: 140px; text-align: center;\"><b>Multicast-IGMP<\/b><\/td>\n<td style=\"width: 287px; text-align: center;\" colspan=\"4\"><b>Related VLANS (4.7)<\/b><\/td>\n<td style=\"width: 216px; text-align: center;\"><b>Sample IP Range<\/b><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 79px; text-align: center;\">A<\/td>\n<td style=\"width: 140px; text-align: center;\">X<\/td>\n<td style=\"width: 287px; text-align: center;\" colspan=\"4\">Vmotion_Network<\/td>\n<td style=\"width: 216px; text-align: center;\">192.168.100.20-30<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 79px; text-align: center;\">B<\/td>\n<td style=\"width: 140px; text-align: center;\">\u2713<\/td>\n<td style=\"width: 287px; text-align: center;\" colspan=\"4\">Vsan_Network<\/td>\n<td style=\"width: 216px; text-align: center;\">192.168.101.20-30<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 79px; text-align: center;\">C<\/td>\n<td style=\"width: 140px; text-align: center;\">X<\/td>\n<td style=\"width: 287px; text-align: center;\" colspan=\"4\">Vm_Network<\/td>\n<td style=\"width: 216px; text-align: center;\">Trunk<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 79px; text-align: center;\">D<\/td>\n<td style=\"width: 140px; text-align: center;\">\u2713<\/td>\n<td style=\"width: 287px; text-align: center;\" colspan=\"4\">The internal _Management_network<\/td>\n<td style=\"width: 216px; text-align: center;\">192.168.102.20-30<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 79px; text-align: center;\">E<\/td>\n<td style=\"width: 140px; text-align: center;\">X<\/td>\n<td style=\"width: 287px; text-align: center;\" colspan=\"4\">External_Management_Network<\/td>\n<td style=\"width: 216px; text-align: center;\">192.168.103.20-30<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 79px; text-align: center;\">F<\/td>\n<td style=\"width: 140px; text-align: center;\">X<\/td>\n<td style=\"width: 287px; text-align: center;\" colspan=\"4\">Idrac_Network<\/td>\n<td style=\"width: 216px; text-align: center;\">192.168.104.20-30<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 79px; text-align: center;\"><b>Vlan<\/b><\/td>\n<td style=\"width: 140px; text-align: center;\"><b>Multicast-IGMP<\/b><\/td>\n<td style=\"width: 287px; text-align: center;\" colspan=\"4\"><b>Related VLANS (VxRail &lt;4.7)<\/b><\/td>\n<td style=\"width: 216px; text-align: center;\"><b>Sample IP Range<\/b><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 79px; text-align: center;\">A<\/td>\n<td style=\"width: 140px; text-align: center;\">X<\/td>\n<td style=\"width: 287px; text-align: center;\" colspan=\"4\">Vmotion_Network<\/td>\n<td style=\"width: 216px; text-align: center;\">192.168.100.20-30<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 79px; text-align: center;\">B<\/td>\n<td style=\"width: 140px; text-align: center;\">\u2713<\/td>\n<td style=\"width: 287px; text-align: center;\" colspan=\"4\">Vsan_Network<\/td>\n<td style=\"width: 216px; text-align: center;\">192.168.101.20-30<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 79px; text-align: center;\">C<\/td>\n<td style=\"width: 140px; text-align: center;\">X<\/td>\n<td style=\"width: 287px; text-align: center;\" colspan=\"4\">Vm_Network<\/td>\n<td style=\"width: 216px; text-align: center;\">Trunk<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 79px; text-align: center;\">D<\/td>\n<td style=\"width: 140px; text-align: center;\">\u2713<\/td>\n<td style=\"width: 287px; text-align: center;\" colspan=\"4\">Management_Network<\/td>\n<td style=\"width: 216px; text-align: center;\">192.168.103.20-30<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 79px; text-align: center;\">E<\/td>\n<td style=\"width: 140px; text-align: center;\">X<\/td>\n<td style=\"width: 287px; text-align: center;\" colspan=\"4\">Idrac_Network<\/td>\n<td style=\"width: 216px; text-align: center;\">192.168.104.20-30<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-size: 18pt;\"><strong>Requirements (DNS)<\/strong><\/span><\/p>\n<table style=\"width: 836px; height: 476px;\" border=\"1\" width=\"714\">\n<tbody>\n<tr style=\"height: 48px;\">\n<td style=\"width: 246px; height: 48px;\"><b>Serve<\/b><b>r Task<\/b><\/td>\n<td style=\"width: 237px; height: 48px;\"><b>Sampl<\/b><b>e Hostname<\/b><\/td>\n<td style=\"width: 153px; height: 48px;\"><b>Exampl<\/b><b>e IP<\/b><b> Address<\/b><\/td>\n<td style=\"width: 172px; height: 48px;\"><b>DNS <\/b><b>(Forward and Reverse)<\/b><\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 246px; height: 48px;\">Vcenter Ip<\/td>\n<td style=\"width: 237px; height: 48px;\">vcenter.fabrikam.local<\/td>\n<td style=\"width: 153px; text-align: center; height: 48px;\">192.168.103.31<\/td>\n<td style=\"text-align: center; width: 172px; height: 48px;\">\u2713<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 246px; height: 48px;\">PSC Ip<\/td>\n<td style=\"width: 237px; height: 48px;\">psc.fabrikam.local<\/td>\n<td style=\"width: 153px; text-align: center; height: 48px;\">192.168.103.32<\/td>\n<td style=\"text-align: center; width: 172px; height: 48px;\">\u2713<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 246px; height: 48px;\">Vxrail Manager<\/td>\n<td style=\"width: 237px; height: 48px;\">vxrail-mgr.fabrikam.local<\/td>\n<td style=\"width: 153px; text-align: center; height: 48px;\">192.168.103.33<\/td>\n<td style=\"text-align: center; width: 172px; height: 48px;\">\u2713<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 246px; height: 48px;\">Vmware Log Insight Ip<\/td>\n<td style=\"width: 237px; height: 48px;\">loginsight.fabrikam.local<\/td>\n<td style=\"width: 153px; text-align: center; height: 48px;\">192.168.103.34<\/td>\n<td style=\"text-align: center; width: 172px; height: 48px;\">\u2713<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 246px; height: 48px;\">Esrs Ip (Emc Account &amp; Site Id)<\/td>\n<td style=\"width: 237px; height: 48px;\">esrs.fabrikam.local<\/td>\n<td style=\"width: 153px; text-align: center; height: 48px;\">192.168.103.35<\/td>\n<td style=\"text-align: center; width: 172px; height: 48px;\">\u2713<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 246px; height: 48px;\">VxRail Node 1<\/td>\n<td style=\"width: 237px; height: 48px;\">vxrail-01.fabrikam.local<\/td>\n<td style=\"width: 153px; text-align: center; height: 48px;\">192.168.103.20<\/td>\n<td style=\"text-align: center; width: 172px; height: 48px;\">\u2713<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 246px; height: 48px;\">VxRail Node 2<\/td>\n<td style=\"width: 237px; height: 48px;\">vxrail-02.fabrikam.local<\/td>\n<td style=\"width: 153px; text-align: center; height: 48px;\">192.168.103.21<\/td>\n<td style=\"text-align: center; width: 172px; height: 48px;\">\u2713<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 246px; height: 48px;\">VxRail Node 3<\/td>\n<td style=\"width: 237px; height: 48px;\">vxrail-03.fabrikam.local<\/td>\n<td style=\"width: 153px; text-align: center; height: 48px;\">192.168.103.22<\/td>\n<td style=\"text-align: center; width: 172px; height: 48px;\">\u2713<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-size: 18pt;\"><strong>Simplified Topology<\/strong><\/span><\/p>\n<p>Below you can see the simplified <strong>VxRail topology<\/strong>. It supports from 2 nodes to 64 nodes.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-674 aligncenter\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vx-simplified.png\" alt=\"\" width=\"426\" height=\"300\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vx-simplified.png 816w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vx-simplified-300x211.png 300w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vx-simplified-768x541.png 768w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vx-simplified-660x465.png 660w\" sizes=\"(max-width: 426px) 100vw, 426px\" \/><\/p>\n<p><span style=\"font-size: 18pt;\"><strong>TCP-IP Configuration Defaults<\/strong><\/span><\/p>\n<table style=\"width: 541px; height: 168px;\" border=\"1\">\n<tbody>\n<tr style=\"height: 24px;\">\n<td style=\"width: 531px; height: 24px;\">Each node must be configured as DHCP for IPv4 and IPv6.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 531px; height: 24px;\">Must be &#8220;Link Local&#8221; (APIPA)<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 531px; height: 24px;\">\u00a0 -169.254.Y.Z for IPv4<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 531px; height: 24px;\">-FE80:: As for IPv6.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 531px; height: 24px;\">Access to VxRail Manager 192.168.10.200<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 531px; height: 48px;\">Static <strong>IP<\/strong> should not be defined for <strong>ESXi<\/strong> hosts unless problem solving situations, configuration must be configured during installation<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-size: 18pt;\"><strong>Demo Setup<\/strong><\/span><\/p>\n<p>Previous requirements cover production environments. In the following stages, some steps may be configured differently or skipped.<\/p>\n<p><span style=\"font-size: 18pt;\"><strong>Edit ESXi Management Network<\/strong><\/span><\/p>\n<table style=\"height: 216px; width: 836px;\" border=\"1\">\n<tbody>\n<tr style=\"height: 24px;\">\n<td style=\"width: 826px; height: 24px;\">Connect to the Server via <strong>IDRAC<\/strong> or keyboard, mouse, monitor.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 826px; height: 24px;\">Activate <strong>ESXi<\/strong> <strong>Shell <\/strong>on<strong> A<\/strong>ll <strong>ESXi<\/strong> hosts.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 826px; height: 24px;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-686\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/esx-mng.png\" alt=\"\" width=\"1235\" height=\"233\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/esx-mng.png 1235w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/esx-mng-300x57.png 300w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/esx-mng-768x145.png 768w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/esx-mng-1024x193.png 1024w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/esx-mng-660x125.png 660w\" sizes=\"(max-width: 1235px) 100vw, 1235px\" \/><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 826px; height: 24px;\">Switch to<strong> ESXi shell<\/strong> and login with <strong>ALT + F1<\/strong> combination.<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 826px; height: 48px;\">Configure the relevant <strong>VLANS<\/strong> for <strong>Management<\/strong> and <strong>VM Network<\/strong> through the following commands.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 826px; height: 24px;\">(Use the <strong>IDRAC<\/strong> virtual keyboard If you experience regional character problems.)<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 826px; height: 24px;\"><em><strong>esxcli network vswitch standard portgroup set \u2013p &#8220;Management Network&#8221; \u2013v &lt;VLANID&gt;<\/strong><\/em><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 826px; height: 24px;\"><em><strong>esxcli network vswitch standard portgroup set \u2013p &#8220;VM Network&#8221; \u2013v &lt;VLANID&gt;<\/strong><\/em><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-size: 18pt;\"><strong>Installation Troubleshooting<\/strong><\/span><\/p>\n<table style=\"height: 168px;\" border=\"1\">\n<tbody>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px; width: 984px;\">Power on all VxRail nodes one by one.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px; width: 984px;\">Type <strong>192.168.10.200 <\/strong>into the browser and start the setup steps.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px; width: 984px;\">If there is no access, check the network settings.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px; width: 984px;\">If you are sure of the correct network settings, Connect using the user name &#8220;<strong>root&#8221; <\/strong>and password &#8220;<strong>Passw0rd<\/strong>!&#8221; to ESXi Web , you can restart <strong>VxRail Manager <\/strong>via <strong>ESXi<\/strong> <strong>Shell<\/strong> unless you want to give static <strong>IP<\/strong> to <strong>ESXi<\/strong>.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px; width: 984px;\">Make sure that you can ping the default <strong>GW<\/strong> by connecting to <strong>VxRail Manager<\/strong> via <strong>SSH (<\/strong>mystic user) or <strong>ESXi Web GUI<\/strong>.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px; width: 984px;\">If<strong>\u00a0VxRail Manager<\/strong> is running but the nodes are not visible then simply run <strong>\/etc\/init.d\/loudmouth restart <\/strong>command through ESXi <strong>Shell<\/strong> and try again. If it still does not appear on<strong>, <\/strong>the Multicast-IGMP settings may not be correct switch side, check it again.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px; width: 984px;\">Sometimes, a node with a different firmware or software level can coincide. In such cases doing <strong>RASR Factory Reset<\/strong> can solve the problem.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-size: 18pt;\"><strong>IDRAC Connection<\/strong><\/span><\/p>\n<p>Define <strong>IP<\/strong> to <strong>IDRAC <\/strong>for each node and provide remote connection to each one with &#8220;<strong>root&#8221;<\/strong> and <strong>&#8220;calvin&#8221;<\/strong> access information.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-690\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/idrac.png\" alt=\"\" width=\"989\" height=\"789\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/idrac.png 989w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/idrac-300x239.png 300w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/idrac-768x613.png 768w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/idrac-660x527.png 660w\" sizes=\"(max-width: 989px) 100vw, 989px\" \/><\/p>\n<p>Access to all servers&#8217; <strong>ESXi Console<\/strong> typing\u00a0<strong>Launch Remote Console<\/strong>.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-692\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/idrac2.png\" alt=\"\" width=\"997\" height=\"511\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/idrac2.png 1175w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/idrac2-300x154.png 300w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/idrac2-768x393.png 768w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/idrac2-1024x525.png 1024w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/idrac2-660x338.png 660w\" sizes=\"(max-width: 997px) 100vw, 997px\" \/><\/p>\n<p>Press <strong>F2<\/strong> and then tyoe username <strong>&#8220;root&#8221;<\/strong> and password <strong>&#8220;Passw0rd!&#8221; <\/strong>to access to the<strong> ESXi<\/strong>\u00a0<strong>Console<\/strong>.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-694\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/idrac3.png\" alt=\"\" width=\"650\" height=\"480\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/idrac3.png 612w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/idrac3-300x222.png 300w\" sizes=\"(max-width: 650px) 100vw, 650px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-693\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/idrac4.png\" alt=\"\" width=\"650\" height=\"466\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/idrac4.png 650w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/idrac4-300x215.png 300w\" sizes=\"(max-width: 650px) 100vw, 650px\" \/><\/p>\n<p><span style=\"font-size: 18pt;\"><strong>ESXi Shell Activation<\/strong><\/span><\/p>\n<p>Under the <strong>Troubleshooting<\/strong> <strong>Options<\/strong> tab, run the<strong> Enable ESXi Shell<\/strong> option.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-696\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/esxi2.png\" alt=\"\" width=\"666\" height=\"485\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/esxi2.png 666w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/esxi2-300x218.png 300w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/esxi2-660x481.png 660w\" sizes=\"(max-width: 666px) 100vw, 666px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-697\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/esxi1.png\" alt=\"\" width=\"661\" height=\"487\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/esxi1.png 656w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/esxi1-300x221.png 300w\" sizes=\"(max-width: 661px) 100vw, 661px\" \/><\/p>\n<p><span style=\"font-size: 18pt;\"><strong>VLAN Configuration<\/strong><\/span><\/p>\n<p>Log in to <strong>ESXi Shel<\/strong>l pressing\u00a0<strong>ALT + F1<\/strong> combination, and perform <strong>VLAN<\/strong> descriptions to management and virtual server networks via <strong>ESXCLI<\/strong>.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-700\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/esxi3.png\" alt=\"\" width=\"891\" height=\"356\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/esxi3.png 891w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/esxi3-300x120.png 300w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/esxi3-768x307.png 768w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/esxi3-660x264.png 660w\" sizes=\"(max-width: 891px) 100vw, 891px\" \/><\/p>\n<p>If you experience regional character problems<strong>,<\/strong> you can\u00a0benefit from the <strong>IDRAC virtual keyboard<\/strong>.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-699\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/esxi4.png\" alt=\"\" width=\"1035\" height=\"68\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/esxi4.png 1035w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/esxi4-300x20.png 300w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/esxi4-768x50.png 768w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/esxi4-1024x67.png 1024w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/esxi4-660x43.png 660w\" sizes=\"(max-width: 1035px) 100vw, 1035px\" \/><\/p>\n<p><span style=\"font-size: 18pt;\"><strong>Start Setup<\/strong><\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-702\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail1.png\" alt=\"\" width=\"712\" height=\"572\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail1.png 712w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail1-300x241.png 300w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail1-660x530.png 660w\" sizes=\"(max-width: 712px) 100vw, 712px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-703\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail2.png\" alt=\"\" width=\"712\" height=\"780\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail2.png 581w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail2-274x300.png 274w\" sizes=\"(max-width: 712px) 100vw, 712px\" \/><\/p>\n<p>If all servers are displayed then continue configuration, if there is a problem, follow the <strong>Setup Troubleshooting<\/strong> steps.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-705\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail3.png\" alt=\"\" width=\"1187\" height=\"491\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail3.png 1187w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail3-300x124.png 300w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail3-768x318.png 768w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail3-1024x424.png 1024w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail3-660x273.png 660w\" sizes=\"(max-width: 1187px) 100vw, 1187px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-706\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail4.png\" alt=\"\" width=\"829\" height=\"545\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail4.png 829w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail4-300x197.png 300w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail4-768x505.png 768w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail4-660x434.png 660w\" sizes=\"(max-width: 829px) 100vw, 829px\" \/><\/p>\n<p>Configure your <strong>DNS<\/strong> and <strong>network card<\/strong> type and continue.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-707\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail5.png\" alt=\"\" width=\"862\" height=\"497\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail5.png 862w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail5-300x173.png 300w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail5-768x443.png 768w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail5-660x381.png 660w\" sizes=\"(max-width: 862px) 100vw, 862px\" \/><\/p>\n<p>Enter <strong>Domain Controller<\/strong>,<strong> ESX<\/strong>i <strong>name<\/strong> <strong>pattern and<\/strong>\u00a0<strong>vCenter<\/strong> <strong>informations<\/strong>, make sure that the host names to be created are queried from <strong>DNS<\/strong>.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-708\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail6.png\" alt=\"\" width=\"677\" height=\"741\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail6.png 677w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail6-274x300.png 274w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail6-660x722.png 660w\" sizes=\"(max-width: 677px) 100vw, 677px\" \/><\/p>\n<p>Enter the relevant network information for <strong>PSC <\/strong>and\u00a0<strong>VxRail Manager<\/strong>, make sure that the host names that will be created are queried from <strong>DNS<\/strong>.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-709\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail7.png\" alt=\"\" width=\"650\" height=\"772\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail7.png 650w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail7-253x300.png 253w\" sizes=\"(max-width: 650px) 100vw, 650px\" \/><\/p>\n<p>Enter the network information to be used for <strong>vMotion<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-710\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail8.png\" alt=\"\" width=\"802\" height=\"325\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail8.png 802w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail8-300x122.png 300w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail8-768x311.png 768w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail8-660x267.png 660w\" sizes=\"(max-width: 802px) 100vw, 802px\" \/><\/p>\n<p>Enter the network information to be used for the <strong>vSAN<\/strong>.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-711\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail9.png\" alt=\"\" width=\"737\" height=\"300\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail9.png 737w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail9-300x122.png 300w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail9-660x269.png 660w\" sizes=\"(max-width: 737px) 100vw, 737px\" \/><\/p>\n<p>Select the network information that virtual servers will access, and setup cannot complete if inaccessible network information is defined.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-712\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail10.png\" alt=\"\" width=\"800\" height=\"327\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail10.png 800w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail10-300x123.png 300w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail10-768x314.png 768w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail10-660x270.png 660w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>Enter the hostname and <strong>IP<\/strong> information required for <strong>LogInsight<\/strong>.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-713\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail11.png\" alt=\"\" width=\"687\" height=\"366\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail11.png 687w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail11-300x160.png 300w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail11-660x352.png 660w\" sizes=\"(max-width: 687px) 100vw, 687px\" \/><\/p>\n<p>Enter the Username and password information.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-714\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail12.png\" alt=\"\" width=\"666\" height=\"827\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail12.png 666w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail12-242x300.png 242w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail12-660x820.png 660w\" sizes=\"(max-width: 666px) 100vw, 666px\" \/><\/p>\n<p>Start the validation process and proceed to the setup step if the validation is successful.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-715\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail13.png\" alt=\"\" width=\"654\" height=\"372\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail13.png 654w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail13-300x171.png 300w\" sizes=\"(max-width: 654px) 100vw, 654px\" \/><\/p>\n<p><strong>Important<\/strong><\/p>\n<p>If the<strong> VxRail<\/strong> <strong>Manager<\/strong> will use an <strong>IP<\/strong> other than default one(192.168.10.200), be sure to configure that secondary <strong>IP<\/strong> to your computer.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-716\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail14.png\" alt=\"\" width=\"654\" height=\"499\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail14.png 654w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail14-300x229.png 300w\" sizes=\"(max-width: 654px) 100vw, 654px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-717\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail15.png\" alt=\"\" width=\"860\" height=\"768\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail15.png 860w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail15-300x268.png 300w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail15-768x686.png 768w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail15-660x589.png 660w\" sizes=\"(max-width: 860px) 100vw, 860px\" \/><\/p>\n<p>You can switch to the management screen when setup completes successfully.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-718\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail16.png\" alt=\"\" width=\"608\" height=\"731\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail16.png 608w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail16-250x300.png 250w\" sizes=\"(max-width: 608px) 100vw, 608px\" \/><\/p>\n<p>Log in to the system with the previously created access information.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-719\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail17.png\" alt=\"\" width=\"460\" height=\"291\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail17.png 460w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail17-300x190.png 300w\" sizes=\"(max-width: 460px) 100vw, 460px\" \/><\/p>\n<p>After checking that All processes are okay, log in to the <strong>vCenter<\/strong>.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-721\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail18.png\" alt=\"\" width=\"1368\" height=\"231\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail18.png 1368w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail18-300x51.png 300w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail18-768x130.png 768w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail18-1024x173.png 1024w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail18-660x111.png 660w\" sizes=\"(max-width: 1368px) 100vw, 1368px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-722\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail19.png\" alt=\"\" width=\"754\" height=\"410\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail19.png 754w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail19-300x163.png 300w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail19-660x359.png 660w\" sizes=\"(max-width: 754px) 100vw, 754px\" \/><\/p>\n<p>By clicking <strong>Set Support Account, <\/strong>support activation is configured.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-723\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail20.png\" alt=\"\" width=\"1410\" height=\"456\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail20.png 1410w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail20-300x97.png 300w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail20-768x248.png 768w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail20-1024x331.png 1024w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail20-660x213.png 660w\" sizes=\"(max-width: 1410px) 100vw, 1410px\" \/><\/p>\n<p>Under<strong> Config-&gt;\u00a0General<\/strong> tab, activation of <strong>ESRS<\/strong> is performed.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-724\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail21.png\" alt=\"\" width=\"1016\" height=\"727\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail21.png 1016w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail21-300x215.png 300w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail21-768x550.png 768w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail21-660x472.png 660w\" sizes=\"(max-width: 1016px) 100vw, 1016px\" \/><\/p>\n<p>Under<strong> VxRail vSAN<\/strong> <strong>Cluster<\/strong>, follow the <strong>Monitor-&gt; vSAN<\/strong> tab to start the Performance monitoring service, perform network performance and virtual server creation tests.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-725\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail22.png\" alt=\"\" width=\"910\" height=\"326\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail22.png 800w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail22-300x108.png 300w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail22-768x276.png 768w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail22-660x237.png 660w\" sizes=\"(max-width: 910px) 100vw, 910px\" \/><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-726\" src=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail23.png\" alt=\"\" width=\"908\" height=\"333\" srcset=\"https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail23.png 908w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail23-300x110.png 300w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail23-768x282.png 768w, https:\/\/blog.arcak.net\/wp-content\/uploads\/2019\/04\/vxrail23-660x242.png 660w\" sizes=\"(max-width: 908px) 100vw, 908px\" \/><\/p>\n<p>The Installation phases end here, enjoy your product:)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>In This article, I will talk about prerequisites, installation and basic issues for VxRail installation. When I created the this document, the VxRail version was 4.5.300. Therefore, it may differ with the current version. (Adding new nodes, ESRS installation, etc.) Requirements (General) Step Definition 1 Complete physical installations of Servers and Switches. 2 Do the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[193,165,167],"tags":[],"class_list":["post-655","post","type-post","status-publish","format-standard","hentry","category-hyperconverged-infrastructure","category-virtualization","category-vmware"],"_links":{"self":[{"href":"https:\/\/blog.arcak.net\/index.php\/wp-json\/wp\/v2\/posts\/655"}],"collection":[{"href":"https:\/\/blog.arcak.net\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.arcak.net\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.arcak.net\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.arcak.net\/index.php\/wp-json\/wp\/v2\/comments?post=655"}],"version-history":[{"count":7,"href":"https:\/\/blog.arcak.net\/index.php\/wp-json\/wp\/v2\/posts\/655\/revisions"}],"predecessor-version":[{"id":735,"href":"https:\/\/blog.arcak.net\/index.php\/wp-json\/wp\/v2\/posts\/655\/revisions\/735"}],"wp:attachment":[{"href":"https:\/\/blog.arcak.net\/index.php\/wp-json\/wp\/v2\/media?parent=655"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.arcak.net\/index.php\/wp-json\/wp\/v2\/categories?post=655"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.arcak.net\/index.php\/wp-json\/wp\/v2\/tags?post=655"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}